Resolution for “RCU-6083” and “RCU-6107” errors while using Repository Creation Utility (RCU).

While creating the Schemas using Repository Creation Utility (RCU), I got the below error –

RCU-6083:Failed - Check prerequisites requirement for selected component:SOAINFRA

RCU-6107:DB Init Param Prerequisite failure for: processes

Current Value is 40. It should be greater than or equal to 200.

Reason: processes Current Value is 40. It should be greater than or equal to 200.

Resolution: Connect to the database as system and alter the value of processes to 300 with the following sql command:

alter system set processes=300 scope=spfile;

If you still gets the same error, Exit the Repository Creation Utility wizard and start it again.

If you still gets the same error, restart the XE database and start the Repository Creation Utility wizard. This time it should work.


Advertisements
This entry was posted in Service Oriented Architecture (SOA 11g), WebLogic Server 11g and tagged , , . Bookmark the permalink.

2 Responses to Resolution for “RCU-6083” and “RCU-6107” errors while using Repository Creation Utility (RCU).

  1. Liwei says:

    Where do we find the value of the processes to change? Thanks.

  2. srinivas says:

    In sqlplus, enter show parameters processes.
    To alter alter system set processes = 1000 scope=spfile

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s